Description
WEH® Filter TSF2 H₂ for installation in H2 fuelling stations, with internal thread on both sides UNF 9/16"-18, 350 bar
Contaminants in the gas flow can enter the vehicle‘s storage tank during refuelling. These dirt particles in the hydrogen fuel may cause damage to the sealing components. WEH, therefore, offers the WEH® TSF2 H2 Filter Series for clean hydrogen.Solid particles are captured reliably.The filter element can be removed and is re-usable after having been cleaned.
The WEH® TSF2 H2 Filter with internal thread on both sides is mainly used for fuelling stations and dispensers and is also available for H2 vehicles.
Features
- For hydrogen free of impurities
- Filter insert can be cleaned
Technical Data
Nominal bore (DN) | 8 mm |
Pressure range | PN = 350 bar (5,000 psi) | PS = 450 bar | PT = 675 bar |
Temperature range | -40 °C up to +85 °C |
Media inlet | UNF 9/16"-18 internal thread, SAE J1926 |
Material | Corrosion resistant stainless steel |
Sealing material | Hydrogen compatible |
Filter element | 40 micron |
Conformity / Tests / Approvals | PED 2014/68/EU |
Part No. | C1-34576 |
Application
Filter with internal thread on both sides for installation in H2 fuelling stations.
Only use filters with EC79 approval for fitment in vehicles!
Only use filters with EC79 approval for fitment in vehicles!